Advertisement

Preliminary evaluation of the effects of a 1:1 inspiratory-to-expiratory ratio in anesthetized and ventilated horses

Published:August 05, 2022DOI:https://doi.org/10.1016/j.vaa.2022.07.009

      Abstract

      Objective

      To describe some cardiorespiratory effects of an inspiratory-to-expiratory (IE) ratio of 1:1 compared with 1:3 in ventilated horses in dorsal recumbency.

      Study design

      Randomized crossover experimental study.

      Animals

      A total of eight anesthetized horses, with 444 (330–485) kg body weight [median (range)].

      Methods

      Horses were ventilated in dorsal recumbency with a tidal volume of 15 mL kg–1 and a respiratory rate of 8 breaths minute–1, and IE ratios of 1:1 (IE1:1) and 1:3 (IE1:3) in random order, each for 25 minutes after applying a recruitment maneuver. Spirometry, arterial blood gases and dobutamine requirements were recorded in all horses during each treatment. Electrical impedance tomography (EIT) data were recorded in four horses and used to generate functional EIT variables including regional ventilation delay index (RVD), a measure of speed of lung inflation, and end-expiratory lung impedance (EELI), an indicator of functional residual capacity (FRC). Results were assessed with linear and generalized linear mixed models.

      Results

      Compared with treatment IE1:3, horses ventilated with treatment IE1:1 had higher mean airway pressures and respiratory system compliance (p < 0.014), while peak, end-inspiratory and driving airway pressures were lower (p < 0.001). No differences in arterial oxygenation or dobutamine requirements were observed. PaCO2 was lower in treatment IE1:1 (p = 0.039). Treatment IE1:1 resulted in lower RVD (p < 0.002) and higher EELI (p = 0.023) than treatment IE1:3.

      Conclusions and clinical relevance

      These results suggest that IE1:1 improved respiratory system mechanics and alveolar ventilation compared with IE1:3, whereas oxygenation and dobutamine requirements were unchanged, although differences were small. In the four horses where EIT was evaluated, IE1:1 led to a faster inflation rate of the lung, possibly the result of increased FRC. The clinical relevance of these findings needs to be further investigated.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Veterinary Anaesthesia and Analgesia
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Auckburally A.
        • Nyman G.
        Review of hypoxaemia in anaesthetized horses: predisposing factors, consequences and management.
        Vet Anaesth Analg. 2017; 44: 397-408
        • Boehme S.
        • Bentley A.H.
        • Hartmann E.K.
        • et al.
        Influence of inspiration to expiration ratio on cyclic recruitment and derecruitment of atelectasis in a saline lavage model of acute respiratory distress syndrome.
        Crit Care Med. 2015; 43: e65-e74
        • Grychtol B.
        • Müller B.
        • Adler A.
        3D EIT image reconstruction with GREIT.
        Physiol Meas. 2016; 37: 785-800
        • Habashi N.M.
        Other approaches to open-lung ventilation: airway pressure release ventilation.
        Crit Care Med. 2005; 33: S228-S240
        • Hinz J.
        • Hahn G.
        • Neumann P.
        • et al.
        End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change.
        Intensive Care Med. 2003; 29: 37-43
        • Kim S.H.
        • Choi Y.S.
        • Lee J.G.
        • et al.
        Effects of a 1:1 inspiratory to expiratory ratio on respiratory mechanics and oxygenation during one-lung ventilation in the lateral decubitus position.
        Anaesth Intensive Care. 2012; 40: 1016-1022
        • Lee S.M.
        • Kim W.H.
        • Ahn H.J.
        • et al.
        The effects of prolonged inspiratory time during one-lung ventilation: a randomised controlled trial.
        Anaesthesia. 2013; 68: 908-916
        • Moens Y.P.
        • Gootjes P.
        • Ionita J.C.
        • et al.
        In vitro validation of a Pitot-based flow meter for the measurement of respiratory volume and flow in large animal anaesthesia.
        Vet Anaesth Analg. 2009; 36: 209-219
        • Muders T.
        • Luepschen H.
        • Zinserling J.
        • et al.
        Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury.
        Crit Care Med. 2012; 40: 903-911
        • Retamal J.
        • Damiani L.F.
        • Basoalto R.
        • et al.
        Physiological and inflammatory consequences of high and low respiratory rate in acute respiratory distress syndrome.
        Acta Anaesthesiol Scand. 2021; 65: 1013-1022
        • Sacks M.
        • Byrne D.P.
        • Herteman N.
        • et al.
        Electrical impedance tomography to measure lung ventilation distribution in healthy horses and horses with left-sided cardiac volume overload.
        J Vet Intern Med. 2021; 35: 2511-2523